Korumalı Fiber Patch Kablo

Korumalı Fiber Optik Patch Cord
Çelik Sprialli ve korumalı fiber optik patch cord talepleriniz için bize ulaşın.
Bina içi uygulamalarda fiber optik kablo çekmek yerine uzun metraj korumalı patch cord kullanarak yapabilirsiniz. Ek işçiliğine ihtiyaç duymazsınız. Kanal içi ve yükseltilmiş taban uygulamarında yada bina içi açık alanlarda tercih edilir. 2 kat koruma olduğu için kolay kolay zarar görmez.

Askı Telli Fiber Optik Kablolar

Askı Telli Multimode Kablolar
2 CORE 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE ASKI TELLİ
4 CORE 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE ASKI TELLİ
6 CORE 62,5/125 ZIRHLIMULTI MODE FIBER OPTIC CABLE ASKI TELLİ
8 CORE 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE ASKI TELLİ
10 CORE 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE ASKI TELLİ
12 CORE 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE ASKI TELLİ

Askı Telli Singlemode Kablolar
2 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE ASKI TELLİ
4 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE ASKI TELLİ
6 CORE ZIRHLISINGLE MODE FIBER OPTIC CABLE ASKI TELLİ
8 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE ASKI TELLİ
10 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE ASKI TELLİ
12 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE ASKI TELLİ

Ergonomic Fiber Optic Stripper

125/250 mikron fiber optik kablo kılıfını soymak için kullanılır. (Used for stripping the 250 micron coating from the 125 micron optical fiber)
Fiber Kablo sıyırıcı (stripper) nedir ?
Fiber Kablonun üst bölümünde bulunan polietilen, aramit iplik gibi malzemelerin fiber tüplerden ayrılmasını sağlamak amacıyla kullanılan alettir.

Loose Tube Cutter; Fiber tüpün dairesel olarak kesilerek fiberlerin ortaya çıkmasını sağlayan kesici alet.

Talepleriniz için bize ulaşın

Jonard JIC-375 Üç Ölçülü Tel Soyma Pensesi

Fiber Optik Soyucu
This Fiber Optic Stripper strips the 1.6-3 mm fiber jacket down to the 600-900 micron buffer coating. The second hole strips the 600-900 micron buffer coating down to the 250 micron coating and the third hole is used to strip the 250 micron cable down to the glass fiber without nicks or scratches.
 
Soyma Kademeleri
  • 1.6-3mm - 900 micron
  • 900 - 250 micron
  • 250 - 125 micron

Talepleriniz için | www.telkolink.com | 0212 320 4030 | 0212 320 0255

Fiber Optik Outlet

Fiber Optik Prizler
SC Tipi : 2xSC Simplex , SC Duplex , 2xSC Duplex
ST Tipi : 2x ST Simplex
LC Tipi : 2x LC Duplex
MTRJ Tipi : 2xMTRJ
E2000 Tipi : 2 *E2000 Simplex + 1 x LC Duplex
Talepleriniz için bize ulaşın

Mode - Conditioning Duplex Jumper

Mode - Conditioning Duplex Jumper
- 2 x ST 50/125µ - 1 x SC 50/125µ - 1 x SC 9/125µ
- 2 x ST 62.5/125µ - 1 x SC 62.5/125µ - 1 x SC 9/125µ
- 2 x SC 50/125µ - 1 x SC 50/125µ - 1 x SC 9/125µ
- 2 x SC 62.5/125µ - 1 x SC 62.5/125µ - 1 x SC 9/125µ
- 2 x ST 50/125µ - 1 x LC 50/125µ - 1 x LC 9/125µ
- 2 x ST 62.5/125µ - 1 x LC 62.5/125µ - 1 x LC 9/125µ
- 2 x SC 50/125µ - 1 x LC 50/125µ - 1 x LC 9/125µ
- 2 x SC 62.5/125µ - 1 x LC 62.5/125µ - 1 x LC 9/125µ


Mode-conditioning patc cordlar 1000Base-LX'de 'Differential Mode Delay'i elimine etmek için kullanılır. Bu jumperlar duplex kablo ile yapılır. Singlemode ucu transmit (gönderici) ucuna takılmalıdır. Multimode fiber altyapı üzerinden 1000Base-LX (singlemode çıkışlı) veri aktarımı yapabilmek için kullanılır. DMD'yi elimine eder. 300 metreden sonra DMD sistemde sorun yaratabilir.
Talepleriniz için bize ulaşın

Epoxy Yapıştırıcı Seti

Epoxy Yapıştırıcı Seti (150ml adhesive, 50ml premier)
Epoxy yöntemi ile fiber optik konnektör sonlandırma işleminde kullanılır.

Ayrıca, fiber optik konnektör sonlandırma / terminasyon işlemi için epoksi takım çantalarıda mevcuttur.

Talepleriniz için bize ulaşın

FIBER OPTIK SONLANDIRMA KİTİ

Pen Cleaver
Stripper
ST-SC Jick
Crimp Tool
Polishing Film
Şırınga
Cam Çalışma Pedi
Hızlı Yapıştırıcı
Makas
Orijinal Çantasında

Detaylı bilgi ve talepleriniz için e-mail gönder

IDEAL 100X MICROSCOPE

IDEAL 45-332 100X MICROSCOPE (Fiber Inspection Microscope)
100X magnification for viewing multimode connectors; Includes 2.5 mm connector inch Universal Adapter inch for FC, ST and SC style connectors; Oblique illumination provides excellent view of ferrule cleanliness and core condition; Rugged, rubberized metal housing, precision glass optics and a built-in laser safety filter; White LED illumination delivers 100,000 hours bulb life; Soft padded carrying case included; Optional 200X Conversion Eyepiece threads on for viewing finish/polish of singlemode connectors

Epoxy yöntemi ile fiber optik kablo uç sonlandırması yaptığınızda yapılan sonlandırmanın uygun olup olmadığını gözleyebilirsiniz.

Talepleriniz için bize ulaşın.

Fiber Optik Mode Dönüştürücü

100MB Fast Etherneti single moddan multimoda yada multimoddan singlemoda dönüştürür. Transmisyon mesafesi 40 km'dir. Optik konnektör tipi SC.


• Fiber portA : Multimode, 850nm, SC/PC
• Fiber portB : Singlemode, 1310nm, SC/PC
• Hız :100Mbps
• Mesafe :40km

Talepleriniz ve sorularınız için e-mail gönder

Fiber optik konnektör ve adaptör temizleme

1.Fiber optik Soket bağlantılarını Temizleme aparatı


2.Stick Temizleyici 1,25 mm 10 luk paketlerde














3.Clauss Alkol içeren Fiber Temizleme Çubuğu 10 St. Miller® FS400


4.Coupler Temizleme Aleti  SC, ST and FC-plug (PC or APC).


The ferrule-cleaner is a tool for cleaninig ferrule surfaces. Thereby the plugs can be not fixed or mounted in an adapter. FO plugs in patch fields don't have to be disassembled. Suitable for SC, ST and FC-plug (PC or APC). By pressing the blue button the cleaning tape will be moved and rotated simultaneosly. Dust and wetness will be removed and not pressed onto the ferrule surface. Conventional cleaning stick move the dirt, whereas the ferrule-cleaner takes and remove it.
For 300 to 400 cleaning cycles

Fiber optik konnektör ve adaptör temizleme ürünleri için firmamıza ulaşın.

Epoxy Yöntemi ile Fiber Sonlandırma Kiti


Included in Kit (English)
Crimper with 2 dies
Die #1 - .042", .068", .133", .162", .195" HEX
Die #2 - .042", .068", .151", .178", .213" HEX
Nick-Free Strippers
Ergonomic Wire Cutters
Kevlar Cutting Scissors
100X-200X Fiber Viewing Scope
SC & ST Polishing Disks
Double-sided Component Storage Box
Swabs
Alcohol Bottle
Syringe
Tweezers
Chisel Tip Carbide Scribe
Zippered Carrying Case

Kit İçeriği (Türkçe) (Bu kit ile SC, ST konnektörler sonlandırılabilir)
Konnektör sıkma pensesi
Kablo soyma pensesi
Kevlar kesme makası
Mikroskop
Konnektör parlatma diskler
Konnektör Kutusu
Konnektör temizleme çubukları
Alkol Kutusu
Şırınga
Fiber cam kesme
Taşima Çantası

Epoxy sonlandırma yapabilmek için ihtiyacınız olan tüm aletler bu kit içinde toplanmıştır. Bunun dışında sarf malzeme olarak epoxy yapıştırıcı ve sprey almanız yeterlidir.


Firmamızdan bu kiti temin edebilirsiniz.

Tek Modlu Fiberi Yapma Prosedürleri

Tek Modlu Fiberi Yapma Prosedürleri
Öncelikle kullanacağımız fiber kablo ve bağlanacak cihazın giriş yâda çıkış portuna göre konektörler belirlenir
Fiber kaplama soyucu kullanılarak kaplama kesilir. Kesilen kaplama çekilerek çıkarılır Kesme işlemi yapmadan önce konektör içinde ne kadarlık kısmının kalacağını dikkatli bir şekilde hesaplanarak yapılmalıdır. Fiber-optik kablonun kaplamasının altındaki iplikler makas ile kesilir.
Miller kesici ile optik kablonun kılıfı kesilir. Kesildikten sonra çekilerek kılıf çıkarılır
Yapıştırıcı olarak kullanılan epoxy iki tüplüdür. Karışım oranını yapıştırıcı ile birlikte gelen kullanma kılavuzuna bakarak iki tüpün içerisindeki kimyasallar karıştırılır. Hazırlanan epoxy şırıngaya çekilerek havası alınır . Havası alınan şırınga içerisindeki epoxy konektör içerisine sıkılır
Fiber-optik kablonun ucu temizlenerek konektör içerisine yerleştirilir. Konektör altındaki somon vida sıkılır. Sağlam bir bağlantının olabilmesi için manşon anahtarı ile iyice sıkılır Sıkma işlemi esnasında fiberin zarar görmemesine dikkat edilir. Oluşturulacak bir çatlak sinyal zayıflamasına neden olur.
Hazırlanan konektör içerisindeki epoxy ısıtıcı kullanılarak kurutulur. Kurutma işlemi çok damarlı fiberlerde hızlı bir şekilde olması gerekir.
Hazırlanan konektörleri fiber ucu düzeltilmesi gerekir. Bunun için fiber ucu scribe adı verilen özel bir kalemle çizilir . Daha sonra konektör ucundaki fazlalık konektör boyuna sıfırlanması için zımpara pedine yerleştirilerek fazlalık dikkatli bir şekilde alınır
konektör ucu mikroskop altına konularak düzleştirme ve sıfırlama işleminin olup olmadığına bakılır
Bağlantı yapılarak OTDR (Optical Time Domain Reflectometre-Optiksel Zaman Domainli Yansıma metre) kullanılarak test edilir
İki fiberi uç uca eklemek için ekleme (splice) aleti kullanılır. Eklenecek fiberler temizlendikten sonra uçlarına epoxy yapıştırıcısı sürülerek bu cihaz içerisinde sıcaklık uygulanarak ekleme işi yapılır
• Fiber kaplama SOYUCU kullanılarak kaplama kesilir.
• Fiber ucu SCRİBE adı verilen bir kalemle çizilir.
• Fiber ucu ZIMPARA PED üstünde düzleştirilir.
• Fiberler SPLİCE içinde eklenir.
• İyonlaştırma ile ekleme yapan aletlere FÜZYON SPLİCE denir

Fiber optik iletişim temel bilgiler için tıklayın

Single Strand Fiber Nedir ?

Dual fiber cihazlarda gönderme ve alma için 2 adet fiber core (kıl) kullanılır. Single strand fiberde ise gönderme ve alma için tek core kullanılır. Tek core içinde 1310nm de gönderme ve 1550nm'de alma yapar. Dolayısı ile tek fiber kıl üzerinden transmisyon gerçekleşir.


Single Strand Fiberin Faydaları
  • Daha az patch cord
  • Daha az fiber terminasyon ekipmanı
  • Daha az işçilik
  • Kolay arıza tespiti
  • Daha az fiber core kullanımı
Bir uctaki media convertörün alışı 1310nm verişi 1550nm iken diğer uçtaki media konvertörün alışı 1550nm verişi 1310nm olmalıdır.
ME61A-S-SC 10/100BaseT(X) to 100 BaseFX Single-Strand Fiber Converter, TX 1310 nm, RX 1550 nm, SC
ME61B-S-SC 10/100BaseT(X) to 100 BaseFX Single-Strand Fiber Converter, TX 1550 nm, RX 1310 nm, SC


Fibre Channel

Fibre Channel ürünlerini firmamızdan tedarik edebilirsiniz. Fibre channellar data storage alanında yoğun olarak kullanılmaktadır.
  • Fibre channel Switchler
  • Ethernet üzerinden fibre channel taşıma
  • Fibre channel üzerinden ethernet taşıma
  • Fibre channelları SDH üzerinden taşıma (Replikasyon için)
  • Fibre Channel patch cordlar
  • Fibre Channel (SAN) Patch Paneller

Fibre Channel Serial 1G
Fibre Channel Serial 2G
Fibre Channel Serial 4G
Fibre Channel Serial 10G

Fibre channel patch kabloların zırh tipi LSZH-FR  olmalıdır.

HSSDC to DB9 Kablo
Loopback Testers
HSSDC 8Pin Male to Male kablo


PC/UPC/APC Arasındaki Fark Nedir ?

Fiber Optik konnektörlerin kontak tipleri
  • PC    :Physical Contact,  –30dB geri yansına (light reflection,ORL)
  • SPC  :Super Physical Contact –40dB geri yansına (light reflection, ORL)
  • UPC  :Ultra Physical Contact, –50dB geri yansına (light reflection, ORL)
  • APC  :Angled Physical Contact, –60dB geri yansına (light reflection, ORL)
Fiber optik konnektör yada pasif elemandan ne kadar az ışık geri dönerse o kadar iyi demektir. Geri yansımalar zayıflamaya ve zayıflamanın sonucu olarakda sistemde bit hatalarına sebep olur. Konnektör (SC, LC, FC, ST, MTRJ etc) , adaptör (SC-SC, LC-LC, FC-FC, SC-FC, SC-ST vs) seçilirken geri dönüş kayıpları dikkate alınmalıdır.

PC (Fhysical Contact) – Genellikle tüm konnektörlerin sonlandırma yüzeylerinde kullanılır. Konnektör fiber merkezi ile arayüz oluşturması için parlatılmış bir dışbükey yüzeye sahiptir
Geçiş Kaybı <= 0.4db
Geri dönüş Kaybı >= 30db
SPC (Super Polished Physical Contact) – Sonlandırma yüzeyi standart fiziksel kontaklara benzer; ancak konnektörün temas yüzeyine geçiş ve geri dönüş kayıplarını geliştirmek için iyi bir parlatma yapılmıştır.
Geçiş Kaybı <= 0.3db
Geri dönüş Kaybı >= 45db
UPC (Ultra Polished Physical Contact) – Sonlandırma yüzeyi standart fiziksel kontaklara benzer; ancak konnektörün temas yüzeyine geçiş ve geri dönüş kayıplarını geliştirmek için extra iyi bir parlatma yapılmıştır.
Geçiş Kaybı <= 0.3db
Geri dönüş Kaybı >= 50db
APC (Angle Polished Physical Contact) – Sonlandırma yüzeyi geometrisi açılı bir yüzeye sahip olup UPC standardında parlatılmıştır. Bu sayede konnektörün geçiş ve geri dönüş kayıpları yüksek kaliteli düşük kayıplı Single Mode sistemlere uygun olarak geliştirilmiştir. APC -konnektörler özellikle single mode sistemlerde kullanılmaktadırlar. Konnektörler, üzerlerindeki YEŞİL renk kodu ile tanınırlar. Genel olarak APC tipi konnektörler FC, SC ve E2000 tipleriyle sınırlıdırlar.
Geçiş Kaybı <= 0.3db
Geri dönüş Kaybı >= 60db
Geri dönüş kaybı (Return Loss) ne anlama gelmektedir?
Işığın konnektör yüzeyinden yansıması ve fibere geri dönüşü ile ilgili ölçüdür; aynı zamanda “Geri Yansıma Kaybı” (Back Reflection Loss) terimi de kullanılmaktadır. Dönüş kaybı desibel (db) birimi ile ölçülür ve ışığı üreten lazeri etkileyerek gürültü problemlerine sebep olduğu için daima Single Mode fiberler için uygun olduğu üreticiler tarafından belirtilir.

Normal dönüş kaybı değerleri 30db – 60db aralığında konnektör tipine ve sonlandırma yüzeyinin parlaklığına göre değişir. Büyüyen dönüş kaybı konnektörün daha iyi olduğunu gösterir ve fibere dönen ışık seviyesini belirler. Geri dönüş kaybı, Multimode sistemlerde ışık kaynağı LED’ler olduğundan Multimode fiberler için önerilmez

Fiber Konnektör Özellikler Dökümanı

Firmamız PC/SPC/UPC/APC konnektör ve patch kabloları temin etmektedir. Talepleriniz için bize ulaşın.

FİBER OPTİK PATCH CORD ÖZELLİKLERİ

o Patch cord’larda ITU-T G.652 D ile tam uyumlu ITU-T G.657 B standartında bükülmeye duyarsız fiberler kullanılmalıdır
o ITU-T G.657 B standartındaki fiberlerde 1550 nm’de, 30 mm çaplı (15 mm yarıçaplı) makarada, 10 sarım sonucu oluşan optik kayıp maksimum 0,03 dB olacaktır.
o Fiber ITU-T G.657 B standartında belirtilen teknik özellikleri sağlayacaktır. Fiber optik üniform bir yapıda olabilmesi için OVD , APVD veya VAD teknolojilerinden biriyle üretilmiş olmalıdır.
o Fiber optik patch cordlar LSZH kılıflı olmalıdır.
o Patch cordlar, 1000 kez adaptöre takılıp çıkartılabilmeli ve 1000 defa takılıp çıkarmada maksimum 0.2 dB değişim olmalıdır.

Patch cord’lar aşağıdaki teknik özelliklerine sahip olmalıdır :
• Çalışma sıcaklığı , -40 / +75 C aralığında olabilmelidir.
• Konektör yuvası Seramik yapıda olmalıdır.
• Zayıflama (1300 nm’de) 0.2 dB olmalıdır.
• Return Loss 50 dB (min) olmalıdır.
o Patch cord’lar 2.8 mm kalınlığında ve kayıp(0.2dbps) özelliğinde olacaktır.

Detay için tıklayın

Optik Kayıp Test Cihazı

Optik Kayıp Test Cihazı ORL 1310nm ve 1550nm dalga boyu testi yapabilir. Telekomünikasyon, CATV ve WAN ve bileşenleri test etmek için kullanılabilir. Sistem işleme sırasında da hataları çözüm sürecini kolaylaştırmak için lif ve optik kalite kaybını test edebilirsiniz.
Ana fonksiyonlar
1. Optik kaybı hassas ölçü
2. Otomatik dalga
3. Mutlak güç testi dBm
4. Çift dalga boyu istikrarlı lazer kaynağı

Fiber optik kaplama teknikleri

1. TIGHT-BUFFERED, (sıkı kılıflı)
Sıkı kılıflı fiberler genellikle bina içlerinde, serbest tüplü fiberler de açık ortamlarda kullanılırlar.
Sıkı kılıflı fiberlerde kılıf malzemesi doğrudan fiberin üzerine kaplanmıştır. Tek fiberli sıkı kılıflı kablolar, bir şebekedeki cihazları bağlamak ya da harici kabloları bina içindeki terminallere bağlamak amacıyla üretilen kısa atlama kabloları için uygundur.
Çok fiberli sıkı kılıflı kablolar ise site ya da kampüs benzeri yerleşimlerde binalar arası bağlantılarda kullanılır. Fiberin sıkı kılıf yöntemi ile kılıflanması, her bir fiberin yerleştirilmesi, konnektörlenmesi vb. işlemlerde fiberi koruyan bir kablo yapısı sağlamaktadır.
2. LOOSE-TUBE, (serbest tüp)
Serbest tüplü kablo tasarımında, optik fiberler plastik tüplerin içinde yer almaktadır. Fiberin uzunluğu tüpün uzunluğunda daha fazla olmakta, böylece fiber, kablonun döşenmesi sırasındaki gerilmelerden ve çevresel yüklerden korunmaktadır. Bu kabloları sağlamlaştırmak için tüpler ya bir yalıtkan malzeme ile sarılmakta ya da bükülmeyi engellemek üzere kablonun merkezinde çelik bir tel bulunmaktadır.

3. GEL-FILLED LOOSE-TUBE (jel dolgulu serbest tüp)
Jel dolgulu serbest tüplü kablolarda, tüp, içine su girmemesi için bir jel ile doldurulmuştur. Jel yerine özel tozların kullanıldığı kablolar da bulunmaktadır.

Patch Kablolar ( Escon, FDDI, MTRJ, D4, E2000)

  • Escon Fiber Patch kablo
  • MU Fiber Patch kablo
  • E2000 Fiber Patch kablo
  • MTRJ Fiber Patch kablo
  • FDDI Fiber Patch kablo
  • D4 Fiber Patch kablo
  • DIN Fiber Patch kablo



Talepleriniz için e-mail gönder

Performans Kriterleri (F/O Multimode ve Single mode kablolarda)

Performans Kriterleri (F / O Multimode ve Single mode kablolarda)
OM1 - Standart 62,5 mikron çok modlu
OM2 - Standart 50 mikron çok modlu
OM3 - Yeni nesil 50 mikron çok modlu
OS1 - 10 mikron tek modlu

Optik kablolarda performans fiber optik kablonun band genişliği ve mesafesini etkilemektedir. Özellikle multimode kablo tercihi yaparken bu kablo üzerinden taşınacak ethernet türü ve taşınacak mesafeyi göz önüne alarak uygun performans kriterinde kablo seçimi yapılmalıdır.

50/125 ve 62.5/125  Multi Mode Fiber Optik Kablo (MultiMode Fiber Optic) İletişim Mesafeleri mesafelerini görmek için tıklayın

Fiber optik kablo talepleriniz için bize ulaşın.

Ethernet Standartları ve Maksimum Mesafeleri

Ethernet Standards (IEEE) Cable Fiber Type Max.Dist (IEEE)
Ethernet (10Base-FL) 50µm or 62.5µm Multimode @ 850nm 2km
Fast Ethernet (100Base-FX) 50µm or 62.5µm Multimode @ 1300nm 2km
Fast Ethernet (100Base-SX) 50µm or 62.5µm Multimode @ 850nm 300m
Gigabit Ethernet (1000Base-SX) 50µm Multimode @ 850nm 550m
Gigabit Ethernet (1000Base-SX) 62.5µm Multimode @ 850nm 220m
Gigabit Ethernet (1000Base-LX) 50µm or 62.5µm Multimode @ 1300nm 550m
Gigabit Ethernet (1000Base-LX) 9µm Singlemode @1310nm 5km
Gigabit Ethernet (1000Base-LH) 9µm Singlemode @1550nm 70km

Fiber Ek Yapımı için Takım Çantası

Takım çantasının içindekiler. Takım olarak firmamızdan temin edebilirsiniz.
Clauss CFS-II Stripper
Clauss Buffer Stripper
Clauss Çok Amaçlı Makas
Clauss Çok Amaçlı Bıçak
Blade Cuts Cable UP to 5/16" Diameter
Fiber Disponsal Unit
Tweezers
RMC-6 Measurrement Scale
Yıldız tornavida takımı
Düz tornavida takımı
Cleaning Tissue
Handy Light (incl.battery)
Heat Gun - ısıtıcı
Filled Cable Cleaning disponsal unit
Alchol disponsal unit
Yan Keski
Pense

Fiber Tools

Fiber Optic Stripper Three Hole
Fiber Optic Stripper - JIC-125
Miller Fiber Sıyırıcı
Miller Pense 125 ' Luk Fiberlerin 250 ' luk kaplamalarını sıyırımak için
CT-30 Series Fiber Cleavers (fiber kesme cihazı)
SUMITOMO FC-6S-C Cleaver (fiber kesici)
JONARD JR-25 Stripper (Fiber Sıyırıcı)
SUMITOMO FC-7S Cleaver (fiber kesici)
Buffer Kesici Ripley
Fiber Optik Sıyırıcı Miller - Ripley

Wall Mount Enclosure TYCO

Plastic Wall Mount Enclosure 2F
Wall Mount Enclosure 2F, SC, Duplex, MM
Wall Mount Enclosure 2F, SC, Duplex, SM

Plastic Wall Mount Enclosure 12/24F
Wall Mount Enclosure 12F, SC, Duplex, MM
Wall Mount Enclosure 12F, SC, Duplex, SM
Wall Mount Enclosure 24F, SC, Duplex, MM
Wall Mount Enclosure 24F, SC, Duplex, SM

Plastic Wall Mount Enclosure 6F
Wall Mount Enclosure 6F, SC, Duplex, MM
Wall Mount Enclosure 6F, SC, Duplex, SM

AMP Fiber Patch Paneller

24 x ST-Style, Multimode; 300 mm deep; Unpopulated 0-1206114-8
24 x ST-Style, Multimode; 300 mm deep; With 12 adapters 2-1206114-4
24 x ST-Style, Multimode; 300 mm deep; With 24 adapters and pigtails (OM2) 4-1206114-0
24 x ST-Style, Multimode; 300 mm deep; With 24 adapters 4-1206114-4
12 x SC Duplex, Multimode; 300 mm deep; unpopulated 0-1206138-8
12 x SC Duplex, Multimode; 300 mm deep; With 6 adapters 2-1206138-4
24 x SC Duplex, Multimode; 300 mm deep; With 24 adapters and 24 pigtails (OM3) 4-1206138-0
12 x SC Duplex, Multimode; 300 mm deep; With 12 adapters 4-1206138-4
24 x SC Duplex, Multimode and Singlemode; 300 mm deep; Unpopulated 0-1206343-4
24 x SC Duplex, Multimode and Singlemode; 300 mm deep; With 24 Multimode adapters 4-1206343-4
24 x ST-Style, Multimode ; 220 mm deep; Unpopulated 0-1206480-8
24 x ST-Style, Multimode; 220 mm deep; With 12 adapters 2-1206480-4
24 x ST-Style, Multimode; 220 mm deep; With 24 adapters 4-1206480-4
12 x SC Duplex, Multimode ; 220 mm deep; unpopulated 0-1206505-8
12 x SC Duplex, Multimode; 220 mm deep; With 6 adapters 2-1206505-4
12 x SC Duplex, Multimode; 220 mm deep; With 12 adapters 4-1206505-4
24 x SC Duplex, Multimode and Singlemode; 300 mm deep; With 24 adapters and 48 pigtails (OM3) 4-1346343-0
12 x SC Duplex, Singlemode; 300 mm deep; With 6 adapters 2-1348960-4
12 x SC Duplex, Singlemode; 300 mm deep; With 12 adapters and 24 pigtails (OM3) 4-1348960-0
12 x SC Duplex, Singlemode; 300 mm deep; With 12 adapters 4-1348960-4
24 x LC Duplex, Singlemode; 300 mm deep; unpopulated 0-1671000-8
24 x LC Duplex, Singlemode; 300 mm deep; With 12 adapters 2-1671000-4
24 x LC Duplex, Multimode; 300 mm deep; With 12 adapters 2-1671000-8
24 x LC Duplex, Singlemode; 300 mm deep; With 24 adapters and 48 pigtails (OS1) 4-1671000-0
24 x LC Duplex, Singlemode; 300 mm deep; with 24 adapters 4-1671000-4
24 x LC Duplex, Multimode; 300 mm deep; With 24 adapters 4-1671000-8
24 x SC Duplex, Multimode and Singlemode; 300 mm deep; With 24 Singlemode adapters 4-1671002-4
12 x SC Duplex, Singlemode; 220 mm deep; With 6 adapters 2-1671017-4
12 x SC Duplex, Singlemode; 220 mm deep; With 12 adapters 4-1671017-4

LSOH ZIRHLI TEK TÜPLÜ SINGLE MODE KABLOLAR

2 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
4 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
6 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
8 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
10 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
12 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
16 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
20 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
24 CORE ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH

Fusion Splicer

Specifications:
Applicable fibers SM, MM, DS, NZ-DS, EDF
Average Splice Loss 0.02dB (SM), 0.01dB(MM), 0.04dB(DS), 0.04dB(NZDS)
Cladding diameter 100 to 150 um
Coating diameter 100 to 1000um
Fiber cleaved length 16mm (standard)
Splicing mode Auto and Manual
Storage 8000 results
Interface RS232, video output
Return Loss ≥60dB
Dimension 160mm(width) x180mm (height) x202mm (depth)
Weight 4.40KG

PON Optical Coupler


Applications
·Optical Fiber Communication Systems
·Optical Fiber CATV
·Passive Optical Network (PON)
·Optical Amplifiers
·Optical Access Networks/LAN
·Monitoring Systems
·Optical Fiber Sensor

Standard Tri-window Optical Couplers
1310±40, 1490±10, 1550±40

Water-Proof Pigtail

SC/APC or FC/APC
Insertion Loss (dB) ≤0.20
Repeatability (dB) ≤0.10
Exchangeability (dB) ≤0.20
Return Loss (dB) ≤45
Fiber Type Corning SMF-28TM, 9/125um
Operating Temperature (℃) -25 ~ +70
Storage temperature (℃) -40 ~ +85
Industrial Standard Telcordia GR-326-CORE

Detaylı bilgi ve talepleriniz için e-mail gönder

1xN SM Optical Coupler 19'rack


Description


•1xN SM coupler 19 is a double window (1310/1550nm) and broadband (±40nm) coupler.
•Low insertion loss, low PDL.
•High directivity, high return loss.
•All-optical structure.
•19 inch 1U framework.

GPJ-02HA Fiber Optic Splice Closure

Optik Kaplama Tekniği

3 tip fiber optik kaplama tekniği bulunmaktadır. Bunlar;

1. TIGHT-BUFFERED, (sıkı kılıflı)
2. LOOSE-TUBE, (serbest tüp)
3. GEL-FILLED LOOSE-TUBE (jel dolgulu serbest tüp)
1. Sıkı kılıflı fiberler genellikle bina içlerinde, serbest tüplü fiberler de açık ortamlarda kullanılırlar.
Sıkı kılıflı fiberlerde kılıf malzemesi doğrudan fiberin üzerine kaplanmıştır. Tek fiberli sıkı kılıflı kablolar, bir şebekedeki cihazları bağlamak ya da harici kabloları bina içindeki terminallere bağlamak amacıyla üretilen kısa atlama kabloları için uygundur.
Çok fiberli sıkı kılıflı kablolar ise site ya da kampüs benzeri yerleşimlerde binalar arası bağlantılarda kullanılır. Fiberin sıkı kılıf yöntemi ile kılıflanması, her bir fiberin yerleştirilmesi, konnektörlenmesi vb. işlemlerde fiberi koruyan bir kablo yapısı sağlamaktadır.
2. Serbest tüplü kablo tasarımında, optik fiberler plastik tüplerin içinde yer almaktadır. Fiberin uzunluğu tüpün uzunluğunda daha fazla olmakta, böylece fiber, kablonun döşenmesi sırasındaki gerilmelerden ve çevresel yüklerden korunmaktadır. Bu kabloları sağlamlaştırmak için tüpler ya bir yalıtkan malzeme ile sarılmakta ya da bükülmeyi engellemek üzere kablonun merkezinde çelik bir tel bulunmaktadır.
3. Jel dolgulu serbest tüplü kablolarda, tüp, içine su girmemesi için bir jel ile doldurulmuştur. Jel yerine özel tozların kullanıldığı kablolar da bulunmaktadır.

MTS-6000 Short Range LAN OTDR 850/1300/1310/1550nm Package

MTS-6000 Short Range LAN OTDR 850/1300/1310/1550nm Package
MTS-6000 Short Range LAN OTDR 850/1300/1310/1550nm Package, including: MTS-6000 platform, E8146SRL Short Range LAN Multimode 850/1300/1310/1550nm OTDR plug-in, EUNIPCSCMM MM Universal PC connector with SC adapter, EUNIPCSC Universal PC connector with SC adapter, ESCASE5 Wrap-around Carrying case for 6000 platform, E80PWE Standard Additional AC Charge/Adapter (Europe), E6000M02 MTS-6000 User Manual Platform (English), E8100M02 User Manual for MTS-8100 plug-ins (English)

EM6000 - MTS-6000 fiber platform
E8146SRL - Short Range LAN 24/24/40/38dB 850/1300/1310/1550nm OTDR

ESCASE5 - Wrap around Carrying case for 6000 platform
E80PWE - Standard Additional AC Adapter/Charger (Europe)
E6000M02 - MTS/TB-6000 & 6000A User Manual Platform (English)
E8100M02 - User Manual for 8000/6000/OTU fiber optic plug-ins (English)
EUNIPCSC - Universal PC connector with SC adapter
EUNIPCSCMM - MM Universal PC connector with SC adapter

OLA-55M Optical Attenuator, singlemode, PC

OLA-55M Optical Attenuator, singlemode, PC Included Items:
2229/90.01 - Alkaline battery Mignon AA-size (LR6): 1.5V -- Qty. 4
2277/90.02 - MT-1S Belt bag SMART handhelds -- Qty. 1 Configuration Choices
BN 2150/00.50, Universal Optical Adapter: DIN 47256
BN 2150/00.51, Universal Optical Adapter: FC-PC, FC-APC
BN 2150/00.58, Universal Optical Adapter: SC-PC, SC-APC
BN 2150/00.59, Universal Optical Adapter: LC

OLA-55M Ayarlanabilir optik zayıflatıcıdır. Bu zayıflatıcı kullanılarak optik sistemlerin alışlarındaki hassasiyet ve sistemi kesme noktası tespit edilebilir. Attenuation range 2-60dB'dir.


OLA-55M talepleriniz için bize ulaşın

Fiber Optik Eğitim

04 ocak 2010 tarihinde başlayacak olan fiber optik eğitimimizin detaylarını öğrenmek yada katılım için tıklayın
Fiber optik haberleşme sistemlerinin avantajlarını ve sistem türleri
Optik fiberde iletimin temel prensipleri ( dalga teorisi, ışın teorisi)
Fiber türlerini ve temel karakteristikleri
Fiberde dispersiyonun etkilerini analizi
Fiberde zayıflama etkilerini analizi
LED ve lazer ışık kaynaklarının çalışma prensiplerini ve temel karakteristikleri
PIN ve APD fotodiyot dedektörlerin çalışma prensiplerini ve temel karakteristikleri
OTDR ile fiber linkin karakterizasyonu
Fiber optik haberleşme sistem tasarımı
FO haberleşme sistemlerinin performansını (SNR, BER) analizi
OTDM ve WDM çoğullama tekniklerinin temel özellikleri
Fiber optik kablonun eklenmesini ve zayıflama testi
Optik spektrum analizör ile fiber optik sistemlerle ilgili test ve ölçümü
http://www.gym-tech.net/egitim/fiber_optik_egitim.pdf

FİBER OPTİK SONLANDIRMA KİTİ

SC Zımpara Diski
Epoksi Mikser Pedi
Kauçuk Çalışma Pedi
Epoksi Mikser
Şırınga
ST Zımpara Diski
A/B Hızlı Epoksi Yapıştırıcı
Temizleyici
Stripper
Karbon Kesici
Sünger
Cam Çalışma Pedi
Crimping Tool
(6um-Kahverengi) Elmas Zımpara Filmi
(1um-Mor) Elmas Zımpara Filmi
(0.05um-Beyaz) Alüminyum Oksit Zımpara Filmi
Kevlar İpi Makası
Kurulama Kağıdı
Kontrol Dürbünü

JDSU-FFL-100 Fiber Hata Tespit Cihazı

Hata Tespit Cihazı, fiber kablolardaki kıvrımları, kırık veya kopukları tespit etmek için kullanılan bir el aletidir.
Cihaz 8.6 inç uzunluğundadır ve çantası ile beraber verilmektedir.
2 adet AA tipi pil ile 80 saat üzerinde çalışabilir.
2,5mm standart SC, ST ve FC konnektör arayüzü ile beraber 1,25mm LC ve MU konnektörler için adaptör mevcuttur.

ETK Fiber Kablo

ETK,2 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE
ETK,4 CORE 50- 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE
ETK,6 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE
ETK,8 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE
ETK,10 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE
ETK,12 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE
ETK,8 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE LSOH
ETK,10 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE LSOH
ETK,12 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE LSOH
ETK,2 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE LSOH
ETK,4 CORE 50- 62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE LSOH
ETK,6 CORE 50-62,5/125 ZIRHLI MULTI MODE FIBER OPTIC CABLE LSOH
ETK,2 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,4 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,6 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,8 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,12 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,16 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,20 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,24 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,36 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,48 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,60CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,72 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,96 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,144 CORE 50-62,5/125 ZIRHLI ÇOK TÜPLÜ MULTI MODE FIBER OPTIC CABLE LSOH
ETK,2 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE
ETK,4 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE
ETK,6 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE
ETK,8 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE
ETK,10 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE
ETK,12 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE
ETK,2 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,4 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,6 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,8 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,10 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,12 CORE 9/125 ZIRHLI SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,2 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE OH
ETK,4 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,6 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,8 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,12 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,16 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,20 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,24 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,36 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,48 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,60 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,72 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,96 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH
ETK,144 CORE 9/125 ZIRHLI ÇOK TÜPLÜ SINGLE MODE FIBER OPTIC CABLE LSOH

EFB F/O Patch Paneller

Fiber Patch panel 24 Port LC 50/125µ n.a. Tam donanımlı
Fiber Patch panel 24 Port ST/ST 50/125µ Tam donanımlı
Fiber Patch panel 24 Port SC/SC 50/125µ Tam donanımlı
Fiber Patch panel 12 Port SC/SC 9/125µ Tam donanımlı
Fiber Patch panel 24 Port SC/SC 9/125µ Tam donanımlı

Estap Fiber Optik Patch Paneller

Estap,19" 1U Açılı patch panel (4 patching), İçi döşenmiş,
Estap,19" 1U Açılı patch panel (6 patching), İçi döşenmiş,
Estap,19" 1U Açılı patch panel (8 patching), İçi döşenmiş,
Estap,19" 1U Açılı patch panel (10 patching), İçi döşenmiş,
Estap,19" 1U Açılı patch panel (12 patching), İçi döşenmiş,
Estap,19" 1U Açılı patch panel (16 patching), İçi döşenmiş,
Estap,19" 1U Açılı patch panel (24 patching), İçi döşenmiş,
Estap,19" 2U Açılı patch panel (4 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (6 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (8 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (10 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (12 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (16 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (24 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (36 patching), , İçi döşenmiş
Estap,19" 2U Açılı patch panel (48 patching), , İçi döşenmiş

Sofetek fiber patch

AL-6LCLC-01I-S LC-LC F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
DK-2633-02 LC-LC F/O Patch Kablo, 2 metre, MM, Duplex, 62.5/125
DK-2633-03 LC-LC F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
DK-2633-05 LC-LC F/O Patch Kablo, 5 metre, MM, Duplex, 62.5/125
DK-2633-10 LC-LC F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
AL-6LCSC-01I-S LC-SC F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
DK-2632-02 LC-SC F/O Patch Kablo, 2 metre, MM, Duplex, 62.5/125
AL-6LCSC-03I-S LC-SC F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
AL-6LCSC-05I-S LC-SC F/O Patch Kablo, 5 metre, MM, Duplex, 62.5/125
AL-6LCSC-10I LC-SC F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
DK-2631-01 LC-ST F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
DK-2631-02 LC-ST F/O Patch Kablo, 2 metre, MM, Duplex, 62.5/125
DK-2631-03 LC-ST F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
DK-2631-05 LC-ST F/O Patch Kablo, 5 metre, MM, Duplex, 62.5/125
DK-2631-10 LC-ST F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
DK-2644-01 MTRJ-MTRJ F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
AL-6MTRJMTRJ-02I-S MTRJ-MTRJ F/O Patch Kablo, 2 metre, MM, Duplex, 62,5/125
DK-2644-03 MTRJ-MTRJ F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
AL-6MTRJMTRJ-05I-S MTRJ-MTRJ F/O Patch Kablo, 5 metre, MM, Duplex, 62,5/125
AL-6MTRJSC-02I MTRJ-SC F/O Patch Kablo, 2 metre, MM, Duplex, 62,5/125
AL-6MTRJSC-03I-S MTRJ-SC F/O Patch Kablo, 3 metre, MM, Duplex, 62,5/125
AL-6MTRJSC-05I-S MTRJ-SC F/O Patch Kablo, 5 metre, MM, Duplex, 62,5/125
AL-6MTRJST-01I MTRJ-ST F/O Patch Kablo, 1 metre, MM, Duplex, 62,5/125
AL-6MTRJST-02I MTRJ-ST F/O Patch Kablo, 2 metre, MM, Duplex, 62,5/125
AL-6MTRJST-03I MTRJ-ST F/O Patch Kablo, 3 metre, MM, Duplex, 62,5/125
AL-6MTRJST-05I-S MTRJ-ST F/O Patch Kablo, 5 metre, MM, Duplex, 62,5/125
AL-6SCSC-01I SC-SC F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
AL-6SCSC-02I SC-SC F/O Patch Kablo, 2 metre, MM, Duplex, 62.5/125
AL-6SCSC-03I SC-SC F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
AL-6SCSC-05I SC-SC F/O Patch Kablo, 5 metre, MM, Duplex, 62.5/125
AL-6SCSC-10I SC-SC F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
AL-6STSC-01 ST-SC F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
AL-6STSC-02I ST-SC F/O Patch Kablo, 2 metre, MM, Duplex, 62.5/125
AL-6STSC-03I ST-SC F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
AL-6STSC-05I ST-SC F/O Patch Kablo, 5 metre, MM, Duplex, 62.5/125
AL-6STSC-10I-S ST-SC F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
AL-6STST-01I ST-ST F/O Patch Kablo, 1 metre, MM, Duplex, 62.5/125
DK-2611-02 ST-ST F/O Patch Kablo, 2 metre, MM, Duplex, 62.5/125
DK-2611-10 ST-ST F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
DK-2611-03 ST-ST F/O Patch Kablo, 3 metre, MM, Duplex, 62.5/125
AL-6STST-05I ST-ST F/O Patch Kablo, 5 metre, MM, Duplex, 62.5/125
AL-6STST-10I-S ST-ST F/O Patch Kablo, 10 metre, MM, Duplex, 62.5/125
DK-2932-01 LC-LC F/O Patch Kablo, 1 metre, SM, Duplex, 9/125
DK-2932-02 LC-LC F/O Patch Kablo, 2 metre, SM, Duplex, 9/125
AL-9LCLC-03I-S LC-LC F/O Patch Kablo, 3 metre, SM, Duplex, 9/125
AL-9LCLC-05I-S LC-LC F/O Patch Kablo, 5 metre, SM, Duplex, 9/125
AL-9LCLC-10I-S LC-LC F/O Patch Kablo, 10 metre, SM, Duplex, 9/125
AL-9LCSC-01I-S LC-SC F/O Patch Kablo, 1 metre, SM, Duplex, 9/125
AL-9LCSC-02I LC-SC F/O Patch Kablo, 2 metre, SM, Duplex, 9/125
AL-9LCSC-03I LC-SC F/O Patch Kablo, 3 metre, SM, Duplex, 9/125
AL-9LCSC-05I-S LC-SC F/O Patch Kablo, 5 metre, SM, Duplex, 9/125
AL-9LCSC-10I-S LC-SC F/O Patch Kablo, 10 metre, SM, Duplex, 9/125
AL-9LCST-01I LC-ST F/O Patch Kablo, 1 metre, SM, Duplex, 9/125
DK-2931-02 LC-ST F/O Patch Kablo, 2 metre, SM, Duplex, 9/125
DK-2931-03 LC-ST F/O Patch Kablo, 3 metre, SM, Duplex, 9/125
AL-9LCST-05I LC-ST F/O Patch Kablo, 5 metre, SM, Duplex, 9/125
AL-9LCST-10I-S LC-ST F/O Patch Kablo, 10 metre, SM, Duplex, 9/125
AL-9SCSC-01I-S SC-SC F/O Patch Kablo, 1 metre, SM, Duplex, 9/125
AL-9SCSC-02I SC-SC F/O Patch Kablo, 2 metre, SM, Duplex, 9/125
AL-9SCSC-03I-S SC-SC F/O Patch Kablo, 3 metre, SM, Duplex, 9/125
AL-9SCSC-05I SC-SC F/O Patch Kablo, 5 metre, SM, Duplex, 9/125
AL-9STSC-01I-S ST-SC F/O Patch Kablo, 1 metre, SM, Duplex, 9/125
AL-9STSC-02I-S ST-SC F/O Patch Kablo, 2 metre, SM, Duplex, 9/125
AL-9STSC-03I ST-SC F/O Patch Kablo, 3 metre, SM, Duplex, 9/125
AL-9STSC-05I-S ST-SC F/O Patch Kablo, 5 metre, SM, Duplex, 9/125
DK-2911-01 ST-ST F/O Patch Kablo, 1 metre, SM, Duplex, 9/125
AL-9STST-02I-S ST-ST F/O Patch Kablo, 2 metre, SM, Duplex, 9/125
AL-9STST-03I-S ST-ST F/O Patch Kablo, 3 metre, SM, Duplex, 9/125
AL-9STST-05I-S ST-ST F/O Patch Kablo, 5 metre, SM, Duplex, 9/125

JDSU Power Metre Seçimi

JDSU'nun Tüm ölçü ve test cihazlarını firmamızdan temin edebilirsiniz.

Fiber optik power metre modelleri
OLP-5 : LAN uygulamaları -60 to +5 dBm.
OLP-6 : Telekom ve Kablolu TV uygulamaları range of -65 to +10 dBm.
OLP-8 :Yüksek optik power ölçümlerinde, -50 to +23 dBm.

Detaylı bilgi ve talepleriniz için e-mail gönder

JDSU Test cihazları Fiber Optik

OVF-1 / VFL Fiber kablolar için görsel arıza konumu belirleyici OVF-1 / Adaptör 1.25mm konektörler için OVF-1 adaptörü
FFL-100 2.5mm ve 1.25mm (SM & MM) görsel arıza konumu belirleyici
FI-11 Fiber tanımlayıcı
OLP-5 Veri hatları için optik power metre
OLP-8 Kapalı devre TV sistemleri için, optik power metre
OLP-6 İletişim hatları için, optik power metre
OLS-5 850/1300nm dalga boyunda optik led kaynağı
OLS-6 / FC-PC 1310/1550nm dalga boyunda optik lazer kaynağı, FC-PC
OLS-6 / SC-PC 1310/1550nm dalga boyunda optik lazer kaynağı, SC-PC
OMK-5 Multimod veri hatları için test kiti, 850/1300nm
OMK-6 / FC-PC Siglemod iletişim hatları için test kiti, FC-PC

Fiber Optik Kırık Bulucu


Sorularınız ve talepleriniz için e-mail gönder

Fiber Optik Splitter


Splitter (Coupler) Sinyal Bölücü
1:2 Gelen işareti 2'ye böler CR %50
1:4 Gelen işareti 4'e böler. CR %25
IL:3  db  1:2 splitter
IL:7.4 db 1:4 splitter
Coupling Ratio (CR) farklı olan splitterlarımızda mevcuttur.

Standart olarak uçları sonlandırılmamıştır. İstediğiniz konnektör tipine göre sonlandırılır.

8/16 Port PLC Splitter

  • PLC Splitter
  • 19'' Rack Tipi
  • 8 yada 16 Port SC/APC
  • Açılı (APC)

FTTH projelerinde yoğun olarak tercih edilmektedir. PDF Dökümanı


Dual Window: hem 1310 hemde 1550nm çalışır.
Single Window: ya 1310nm yada 1550nm çalışır (tercihinize bağlı)


Geçiş kaybı (Insertion Loss – IL) ne anlama gelmektedir?
Bağlantıdaki ışık kaybının desibel (db) cinsinden ölçüsüdür. Kayıp genellikle konnektör çiftlerine göre belirlenmektedir. Tipik geçiş kaybı değerleri fiber ve konnektör tipine göre 0.2db – 0.5db arasında değişmektedir

C ve L Bandı splitter ürünlerimiz hakkında bilgi almak için e-mail gönder

Fiber Optic Connector Cleaner

Neoclean-N | Fiber Optik Konnektör Temizleyici
Fiber optik konnektörlerin temizlenmesi için kullanılır. Fiber optik konnektörleri temizleyerek hatta oluşan güç kayıplarını (zayıflamayı) azaltarak hatta oluşabilecek Bit hatalarının önüne geçebilirsiniz. iyi bir fiber kablolamada tüm konnektörler temiz olmalıdır. Aksi takdirde zamanla hattaki zayıflamalar artar ve hattan hatalar gelmeye başlar.

İletişim Bilgilerimiz


www.telkolink.com | 0212 320 4030 | 0212 320 0255 | yusuf@telkolink.com

MTP/MPO IBC (In Bulkhead Cleaner)

Dry cloth cleaner utilizes densely woven micro-fiber cloth
● Cleans male (with pins) or female MTP/MPO connectors in adapters,
bulkheads, and faceplates
● Pre-washed cleaning cloth is lint and debris free
● Each cleaner is capable of more than 400 cleanings
● Protective dust cover doubles as an adapter cap for cleaning unmated
connectors
● FOCIS 5-Type MTP/MPO interface compliant
● Removes dust and oil contamination
PART NUMBER 1918809-1

Fiberoptic Stripper / Fiberoptik Sıyırıcı - Sıyırma Aleti

Fiberoptik kabloların izolasyonun sıyrılması ve kesme işlemleri için Jonard'ın fiberoptik sıyırma aletini kullanabilirsiniz.

Ençok Okunanlar